Muhammad Imran Khan , Ghulam Murtaza *, Sher Awan , Muhammad Iqbal , Muhammad Khurram Waqas , Akhtar Rasool , Urooj Fatima , Muhammad Hassham Hassan Bin Asad , Anwar Kahlid , Faisal Usman , Qazi Najam-us -Saqib , Shujaat Ali Khan , Kalsoom Farzana , Seema Mahmood
and Izhar Hussain2
A new simple and rapid high performance liquid chromatography (HPLC) method was developed for the determination of cetirizine hydrochloride (CTZ) in tablets using CLC-ODS reverse phase column (4.6 × 250 mm, 5 µm). Salicylic acid was used as internal standard. A mixture of methanol and water of 70:30 with pH 4 (adjusted with o-phosphoric acid) was used as mobile phase. The eluents were detected at 231 nm. The coefficient of determination of calibration curve for CTZ and salicylic acid in mobile phase were 0.9898 and 0.9925, respectively. The limit of detection for CTZ was 4 µg ml-1 . The proposed method was successfully applied for the stability study of CTZ. The CTZ was found to be stable at accelerated condition of temperature and relative humidity after storage of six months. This method can be used for the routine quality control and dosage form assay of CTZ in pharmaceutical preparations.
Share this article
Select your language of interest to view the total content in your interested language